top of page
PhoenixTM 10Ch CAB & Vacuum Brazing Temperature Profile System

PhoenixTM 10Ch CAB & Vacuum Brazing Temperature Profile System

SKU : HTS08-125-10

Application :  Aluminum Brazing, Controlled Atmosphere Brazing (CAB) and Vacuum Brazing

  • PTM1-210-K  l  10 Channel Data Logger, temperature measuring range -100°C to +1370°C, type K, standard temperature operation.

    Accuracy +/- 0.3°C, resolution 0.1°C.

    Total memory 3.8M data points of non-volatile memory over 10 channels.

    Sampling interval 0.2s to 60 minutes on all selected channels.

    Maximum ambient operating temperature 80°C.

    Original calibration certificate and correction factors stored in memory for access as required.

    Up to 1000 hours battery life from 2 x ‘AA’ Alkaline Standard Batteries.

    Bluetooth connectivity,

    USB communication cable included.

    Optional upgrade to two way real time telemetry (PTM telemetry system required).

    Dimensions: 200mm(L) x 98mm(W) x 20mm(H).

bottom of page